Skip to content

AC to DC Power Supplies

AS200 Series

Category
AC to DC Power Supplies
Type
Rugged Environment Switchers
Power
200 Watts
AS200 Series 200 W AC to DC power supply

AS200 Series Introduction

High Efficiency, Compact Size, Customer Configurable.

Currently serving in many active programs with dozens of configurations, the AS200 Series features Power Factor Correction and is designed to perform in extreme environments. Designed to meet MIL-S-901 High Impact Shock and MIL-STD-810 Environmental Requirements, MIL-STD-704 and MIL-STD-1399 Input Requirements, MIL-STD-461 CE101, CE102 EMI Requirements.

This series’ standard configuration features Over-Temperature Protection, Short Circuit Protection, Remote Error Sensing, Control Features, and Built-in Test Features.

This unit is Factory Configurable both electrically and mechanically to best fit your application.

Key Features

  • Wide Input Range
  • Power Factor Correction
  • MIL-STD-1399 Section 300 Type 1 Requirements
  • MIL-STD-461 CE101, CE102
  • MIL-S-901 High Impact Shock
  • MIL-STD-810 Environmental Requirements
  • MIL-STD-167 Vibration Requirements

Specifications

AC Input95-260 VAC, 47-440Hz, Single Phase
Power Factor Corrected
MIL-STD-1399, Section 300, Type 1 Requirements
EFFICIENCY80% Minimum (90% Typical, 28 VDC Model at 100% Load)
LINE REGULATION±1% of Nominal over the Full Range of Line Input Voltage
LOAD REGULATION±1% for Change from no Load to Full Load
RIPPLE AND NOISEPeak-to-Peak Combined Ripple and Noise does not Exceed 2% of Nominal Output Measured with a 20 MHz Bandwidth
Isolation
INPUT TO OUTPUT1500 VDC
INPUT TO CASE1500 VDC
OUTPUT TO CASE500 VDC
INPUT PROTECTIONInternal Fuse. In-rush Current Limiting. Transient Protection.
SHORT CIRCUIT PROTECTIONEach unit is completely protected against a short circuit of any duration. The current limit is nominally set at 120% of full load. The output voltage automatically restores to normal when the short is removed.
REMOTE ERROR SENSINGStandard
CONTROL FEATURESENABLE, INHIBIT (TTL LOW = TRUE)
Standard TTL, 3.3V Available upon Request
BUILT-IN TEST FEATUREOutput Fault Alarm (TTL LOW = FAULT)
DC OK on J1-10
TEMPERATURE RANGE
(NO POWER DERATING)
Storage, Transport and Handling:
-50°C to +85°C
Conduction Cooled Baseplate Temperature, No Power Derating:
-40°C to +70°C
Over-Temperature ProtectionOutput shut down if maximum case temperature limit is exceeded
MEAN TIME BETWEEN FAILURE (MTBF)109,000 Hours at 25°C Ambient (calculated per MIL-HDBK-217 in naval sheltered environment)
Electromagnetic CompatibilityMIL-STD-461 requirements: CE101, CE102
CONNECTORSJ1: Positronic Industries GFSH109M3H (GFSH109M4B Horizontal Configuration); see pin assignments below
Additional Connectors Available upon Request
STANDARD OUTPUTS (VDC)12, 13.6, 15, 24, 28, 48 (Additional Voltages Available upon Request)
Options include Droop (Zero Wire) Current Sharing and Internal ORing Diode
MATERIALAluminum Alloy 6061-T6 Case
WEIGHT2 lbs typical
FINISHBlack 27041
Sand 33303
Green 383
Gray 151
ENVIRONMENTMIL-S-901 (High Impact Shock, Lightweight)
MIL-STD-167, Type 1 Requirements
Applicable MIL-STD-810 Environmental Requirements
Power supply operates without any evidence of degraded performance in non-condensing relative humidity up to 95%. For condensing-environment requirements, consult ATI for the applicable configuration.

Find a Part Number

Choose any option to narrow the list. Only combinations that exist can be selected.

Rated Power (W)
200
Configuration
S: Standard
Finish
Black 27041 (standard)
Input
95-260 VAC, 47-440 Hz, single phase, power factor corrected
Part Number Output Current (A) NSN Quote
AS200S1216.67NoneQuote
Output Voltage 12 VDC Connector Orientation Vertical connector (standard)
AS200S12H16.67NoneQuote
Output Voltage 12 VDC Connector Orientation H: Horizontal connector
AS200S13.614.7NoneQuote
Output Voltage 13.6 VDC Connector Orientation Vertical connector (standard)
AS200S13.6H14.7NoneQuote
Output Voltage 13.6 VDC Connector Orientation H: Horizontal connector
AS200S1513.33NoneQuote
Output Voltage 15 VDC Connector Orientation Vertical connector (standard)
AS200S15H13.33NoneQuote
Output Voltage 15 VDC Connector Orientation H: Horizontal connector
AS200S248.331680-01-644-7188Quote
Output Voltage 24 VDC Connector Orientation Vertical connector (standard)
AS200S24H8.33NoneQuote
Output Voltage 24 VDC Connector Orientation H: Horizontal connector
AS200S287.141680-01-578-2559Quote
Output Voltage 28 VDC Connector Orientation Vertical connector (standard)
AS200S28H7.141680-01-644-7202Quote
Output Voltage 28 VDC Connector Orientation H: Horizontal connector
AS200S484.17NoneQuote
Output Voltage 48 VDC Connector Orientation Vertical connector (standard)
AS200S48H4.17NoneQuote
Output Voltage 48 VDC Connector Orientation H: Horizontal connector

Part numbers are listed for quotation. Configuration, availability and qualification are confirmed on the quote.

Need a value or option not listed? Request a quote for a modified unit.

Mechanical Drawings

AS200 Series mechanical drawing

Model Number System

AS200 Series model number system and output ratings

Images

Have additional questions about the AS200 Series?

Speak with our Application Engineers

AS200 Series Functions and Connections

J1-5 CHASSIS GNDInternally wired to chassis of unit.
J1-6 CHASSIS GNDInternally wired to chassis of unit.
J1-7 NINHIBITInhibits output of unit when pulled low.
J1-8 NENABLEEnables output of unit when pulled low.
J1-9 (SPARE)No Connection
J1-10 DCOK+5VDC Signal when DC Output is within range. Pulls to active low (20mA maximum sink current) when DC Output is outside of Nominal Range.

Optional +3.3V, +12V signals available
J1-11 (SPARE)No Connection
J1-12 (SPARE)No Connection
J1-13 +SENSEPositive Sense Line provides point-of-use output voltage feedback signal to unit when tied to (+) side of output load to compensate for voltage drop of output cables under load.

(+) and (-) sense lines should be routed as a twisted pair to mitigate pickup of ambient electrical noise (EMI).

Sense lines must be connected on power supply side of any output protection devices, fuses, circuit breakers, switches, relays, etc which may interrupt DC Output Current Path.
J1-14 -SENSENegative Sense Line (See J1-13 above).
J1-15 (SPARE)No Connection
Standard Power Supply Notes

Abbott AC-DC switchers are designed to operate in a rugged military environment where a high degree of isolation, regulation and thermal performance is required. The extreme low-profile of these modules makes them an ideal choice in applications where space is limited, and reliability is a chief concern. These switchers represent a cost-effective, off-the-shelf alternative to costly DC-DC arrays. The units are designed to meet MIL-STD-461 CE101, CE102, MIL-S-901 (high impact shock), MIL-STD-810 and MIL-STD-1399, Section 300, type I requirements (spike voltage test).

Among key standard features are input power factor correction, full cycle holdup during power interruption, soft start/controlled inrush, and on-board in-line fuse. These state-of-the-art AC-DC switchers are well-suited for airborne, ground or shipboard systems.

Key Terms

Ambient Temperature – the temperature of the still air surrounding a power supply, measured a minimum of 4 inches (10.2 cm) from the supply. Note that these Abbott supplies are conduction-cooled and that temperature specifications refer to baseplate temperature, not ambient temperature.

Efficiency – the ratio of total output power, expressed as a percentage. Efficiency must be
specified at a specific combination of load and input voltage.

Isolation – the electrical separation between the input and output of a power supply due primarily to the power transformer. The isolation is a function of materials and spacing throughout the supply.

Line Regulation – the maximum change in output voltage, expressed as a percentage of output voltage, that occurs as the input voltage varies over its specified limits, with load and temperature constant.

Load Regulation – the change in output voltage, expressed as a percentage of output voltage, that occurs as the load changes from minimum to maximum, at constant line and constant temperature. Load change may be specified for other than no load to full load as, for example, 50% load to full load.

Mean Time Between Failure (MTBF) – the failure rate of a power supply, expressed in hours, predicted as prescribed by MIL-HDBK-217.

Periodic and Random Deviation (PARD), or Ripple and Noise – the unwanted periodic (ripple) or aperiodic (noise) deviation on the power supply output voltage from its nominal value. Ripple is a function of the input line and switching components. PARD is expressed in millivolts peak-to-peak or rms, at a specified bandwidth (typically 20 MHz).

Over-Voltage Protection (OVP) – a protective feature that shuts down a power supply (reduces the output voltage to a minimal level) to prevent damage to the load when the output voltage exceeds a predetermined limit.

Short-Circuit Protection – a protective feature that limits the output current of a power supply to prevent damage to the supply caused by short circuits. There are two types of short-circuit, or overload, protection depending on the power supply:

  • Foldback Current Limiting protects switching regulator power supplies from damage when an overload occurs by reducing, or folding back, both the output voltage and current as the load.
    resistance ranges from maximum to short circuit.
  • Constant Limiting Current protects power supplies from damage when an overload occurs by holding the output at a constant predetermined maximum current level.