TL Power Inductors

 

MILITARY CONSTRUCTION:
Encapsulated to meet construction
requirements of MIL-PRF-27F * Type
TF5S04ZZ. 

APPLICATION:

These inductors have low losses in
the 3 to 100 KHz frequency range,
making them ideal for switching
regulator and AC filter choke applications.



INDUCTANCE:
Part numbers correspond to
inductance values in microhenries,
which are measured at 1 V , 10 KHz, 0
DC with an inductance tolerance of
+15%, -5%. V alues of inductance
other than listed in an existing size
are available. Part Number would be:
TL(A, B, or C) – (inductance in
Microhenries at 0 DC). 

CURRENT RATINGS:

Listing I 1, is for approximately 10%
drop in Inductance with a typical 20
degree C temperature rise, and Listing
I2 is for approximately 20% drop in
inductance with a typical 40 degree C
temperature rise.