60 Hz MIL-PRF-27 Power Transformers 6C

  • 6C photo copyMIL-PRF-27 GRADE 4 CLASS S CONSTRUCTION
  • HERMETICALLY SEALED, RUGGED CONSTRUCTION
  • STANDARD OUTPUT VOLTAGES: 5-120 VAC
  • TRADITIONAL MIL-T-27 CAN SIZES AND MOUNTING STYLE
  • POWER RATINGS FROM 5-170 VA

Input Primary:
115 V ac, 50 to 65 Hz, 1 phase. (These units are capable of 400 Hz operation.)

“A” Option: 230 V ac. Add suffix “A” to model number, e.g., 6C5-5A.

“X” Option: Electrostatic shield grounded to case and Pin 7. Add suffix “X” to model number, e.g., 6C5-5X.

Regulation:
10% or less no load to full load.

Secondary Voltage Tolerance:
Within 3% of listed output voltage when measured at full load and listed input.

Dielectric Withstanding Voltage:
1500 V ac.

Efficiency:
Ranges from 80% to 90% typical.

Operating Ambient Temperature:
90° C maximum.

Construction:
To MIL-PRF-27, Grade 4, Class S; steel case.

Environment:
Encapsulated to meet MIL-STD-810 for vibration, shock, acceleration, sand, dust, humidity, saltspray, fungus, sunshine, rain, explosion, and altitude (to a vacuum).
NOTE: For high altitude operation, encapsulate terminals.

Output Secondary:
See output voltage and current of specific models listed.
Other outputs and/or inputs available upon request.