400 Hz 3 Phase AC to DC Transformer Rectifier (Inherent Harmonic Suppression)

• ML-STD, MIL-STD-704 compliant
• Passive power factor correction
• Low parts count for high MTBF up to 500,000 hours (airborne environment)
• Rugged construction, MIL-810 compliant
• MIL-STD-167, MIL-STF-202 G compliant (conduction or air cooled)
• RTCA DO-160 D

AC INPUT PRIMARY:

115V DELTA Suffix A

115/200V WYE or 200V DELTA Suffix B

EFFICIENCY:

24, 28, 280, 300 Other voltages are available

upon request.

LINE REGULATION:

0.2% for full input charge between 90 and

132 or 180 and 254 Vrms. Temperature

and load constant.

LOAD REGULATION:

Main output – 0.2%; other regulated outputs,

1%; semi-regulated outputs, ± 10%

INPUT FREQUENCY:

400HZ, 3 Phase. Power factor corrected.



ISOLATION:

Input to Output 1000 VDC
Input to Case 1000 VDC
Output to Case 500 VDC

ENVIRONMENT:
Contructed to meet MIL-STD-810 for

vibration, shock, acceleration, fungus,

sunshine, and sltitdue. (Sand, dust,

humidity, saltsspray, rain, explosion -

A, C and H cooling only)

MOUNTING PROVISIONS:

Flage mounting captive inserts.

 


REMOTE ERROR SENSING:

Regulator monitors the voltage of Output No. 1

Directly at the load using extra “Sensing” leads

and compensates for a DC voltage drop up to 0.3

Volts in the load leads.


OPERATING TEMPERATURE:
Unregulated Units: -40ºC to + 85ºC

Regulated Units: -40ºC tp +70ºC