200 Watt AC-DC Switchers AS200
• Power Factor Correction
• Fully compliant with MIL-STD 461D, CE101, CE102
• Meets MIL-S-901 (High Impact shock)
• Meets MIL-STD-810F
• FCC 20780 class A EMI compliance
• Compact PCI option available
• IP67 sealed option available

95-260 VAC 47-880 Hz single phase. Power
factor corrected. Meets MIL-STD-1399,
Section 300, type I requirements
(spike voltage test).
EFFICIENCY:
80% minimum or greater.
LINE REGULATION:
±1% of nominal over the full
range of line input voltage.
LOAD REGULATION:
± 1% for change from no load to full load.
RIPPLE AND NOISE:
Peak-to-peak combines ripple and noise
does not exceed 2% of nominal on the
output measured with a 20 MHz bandwidth.
Storage, transportation and handling: – 50° to
+85°C. Ambient temperature: -40°C to +70°C
baseplate with no power derating.
ISOLATION:
The input power circuits and DC output voltage
lines are isolated from the chassis.
Isolation voltage 500 VDC.
SHORT CIRCUIT PROTECTION:
Each unit is completely protected against a
short circuit of any duration. The current limit
circuit is nominally set at 120% of full load to
reduce voltage. The output voltage
automatically restores to normal when the short
is removed.
INPUT PROTECTION:
Internal fuse. In-rush current limiting.
REMOTE ERROR SENSING:
Standard.
“INHIBIT”, “ENABLE” (STANDARD) (TTL LOW = TRUE)
BUILT-IN-TEST FEATURE:
OUTPUT FAULT ALARM (TTL LOW = FAULT)
RELIABILITY:
MTBF 40,000 hours calculated per MIL-HDBK-217F in
naval sheltered environment.
ELECTROMAGNETIC COMPATIBILITY:
Meets the following MIL-STD-461D requirements: CE101,
CE102.
OUTLINE DIMENSIONS:
Refer to mechanical drawings.
WEIGHT:
2 lbs typical.
ENVIRONMENTAL CONDITIONS:
Shock test: Unit meets MIL-S-901 requirements (light
weight).
Vibration test: Unit meets MIL-STD-167,
type I requirements.
Humidity: Power supply operates without any evidence of
degraded performance in non-condensing relative humidity up to 95%.