11 to 54 Volt Input to 115 VAC 60 Hz or 220 VAC 50 Hz output from 30 to 320 VA Sine Wave Inverters
• Low Distortion. 5% Maximum
• Exceptional Reliability. Typical MTBF: 90,586 hours for model LN8
• Surge Current Capabilities, up to 3 times rated output power
• High Efficiency, provided by sine wave, conserves power
• Switchable 115 VAC 60 Hz / 230 VAC 50 Hz
• Saves Motors by Reducing Overheating
INPUT VOLTAGE RANGE:
KN, KS: 11 to 15 VDC
PN, PS: 22 to 30 VDC
LN, LS” 29 to 38 VDC
TN, TS: 42 to 54 VDC
EFFICIENCY:
At full load with nominal input voltage.
40% minimum on KN, KS
50% minimum on PN, PS
58% minimum on LN, LS
60% minimum on TN, TS
LINE REGULATION:
3% for specified input voltage range with load
constant.
ISOLATION:
Input to Output 1000 VDC
Input to Case 1000 VDC
Output to Case 500 VDC
ENVIRONMENT:
Contructed to meet MIL-STD-810 for
vibration, shock, acceleration, fungus,
sunshine, and sltitdue. (Sand, dust,
humidity, saltsspray, rain, explosion -
A, C and H cooling only)
WAVE FORM:
Sine wave with 2% distortion typical. 5%
distortion maximum.
Overload PROTECTION:
Magnetic type circuit breaker. Reverse polarity protection.
OPERATING TEMPERATURE:
(KN, PN, LN and TN): -20ºC to + 55ºC ambient air temperature.
Humidity 0 to 90% (non condensing at 25ºC
(KS, PS, LS and TS): -20ºC to + 55ºC ambient air temperature.
Humidity 0 to 100%
INPUT FREQUENCY:
400HZ, 3 Phase. Power factor corrected.
LOAD REGULATION:
3% for load change of half load to full load with
the line constant; 6% for change of no load to full
load.