200 Watt AC to DC Switchers AS200

AS200

  • Power Factor Correction
  • Fully compliant with MIL-STD-461, CE101, CE102
  • Meets MIL-S-901 (High Impact shock)
  • Meets MIL-STD-810
  • FCC 20780 class A EMI compliance
  • Compact PCI option available
  • IP65/IP67 models available (see AM200 line)

AC INPUT:
95-260 VAC 47-440Hz single phase. Power factor corrected. Meets MIL-STD-1399, Section 300, type I requirements (spike voltage test).

EFFICIENCY:
80% minimum or greater.

LINE REGULATION:
±1% of nominal over the full range of line input voltage.

LOAD REGULATION:
±1% for change from no load to full load.

RIPPLE AND NOISE:
Peak-to-peak combines ripple and noise does not exceed 2% of nominal on the output measured with a 20 MHz bandwidth.

OPERATING TEMPERATURE RANGE:
Storage, transportation and handling: – 50° to +85°C. Ambient temperature: -40°C to +70°C baseplate with no power derating.

ISOLATION:
The input power circuits and DC output voltage lines are isolated from the chassis. Isolation voltage 500 VDC.

SHORT CIRCUIT PROTECTION:
Each unit is completely protected against a short circuit of any duration. The current limit circuit is nominally set at 120% of full load to reduce voltage. The output voltage automatically restores to normal when the short is removed.

INPUT PROTECTION:
Internal fuse. In-rush current limiting.

REMOTE ERROR SENSING:
Standard.

CONTROL FEATURES:
Inhibit and enable (STANDARD) (TTL LOW = TRUE)

BUILT-IN-TEST FEATURE:
OUTPUT FAULT ALARM (TTL LOW = FAULT)

RELIABILITY:
MTBF 109,000 hours calculated per MIL-HDBK-217 in naval sheltered environment.

ELECTROMAGNETIC COMPATIBILITY:
Meets the following MIL-STD-461 requirements: CE101, CE102.

OUTLINE DIMENSIONS:
Refer to mechanical drawings.

WEIGHT:
2 lbs typical.

ENVIRONMENTAL CONDITIONS:
Shock test: Unit meets MIL-S-901 requirements (light weight).

Vibration test: Unit meets MIL-STD-167, type I requirements.

Humidity: Power supply operates without any evidence of degraded performance in non-condensing relative humidity up to 95%.

PDF